A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.00…

cve CVE-2025-14136 1 source, 1 claim · Watch

NVD writes:
A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way. the claim
Severity
HIGH NVD
CVSS
8.8 NVD
Vendor
Linksys NVD
Product
RE6500 NVD
CWE
CWE-119, CWE-121, CWE-787 NVD

How far exploitation has got

  1. No public code known
  2. Proof of concept
  3. Proof of concept, verified
  4. A Metasploit module
  5. Exploited in the wild
  6. Used in ransomware campaigns

Timeline

2025-12-06first spoke of it: A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.NVD

A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

What it is to other things

affectslinksys/re6250
NVD
affectslinksys/re6250_firmware
NVD
affectslinksys/re6300
NVD
affectslinksys/re6300_firmware
NVD
affectslinksys/re6350
NVD
affectslinksys/re6350_firmware
NVD
affectslinksys/re6500
NVD
affectslinksys/re6500_firmware
NVD
affectslinksys/re7000
NVD
affectslinksys/re7000_firmware
NVD
affectslinksys/re9000
NVD
affectslinksys/re9000_firmware
NVD
made_bylinksys
NVD
Every value, with what each source said and its receipt
PropertySourceSaidMeans here
Automatable
automatable
NVDno
At least one of those steps needs a person.
receipt
Source
NVD
Its words
no
Read by
field:cve.metrics.ssvcV203[].ssvcData.options[].automatable
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCno
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
CVSS
cvss
NVD8.8
receipt
Source
NVD
Its words
8.8
Read by
field:cve.metrics.cvssMetricV31[type=Primary].cvssData.baseScore || field:cve.metrics.cvssMetricV31[].cvssData.baseScore
Said since
2026-09-29 09:45 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Cvss4
cvss4
NVD7.4
receipt
Source
NVD
Its words
7.4
Read by
field:cve.metrics.cvssMetricV40[type=Primary].cvssData.baseScore || field:cve.metrics.cvssMetricV40[].cvssData.baseScore
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTC7.4
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Cvss4 vector
cvss4_vector
NVDCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
receipt
Source
NVD
Its words
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Read by
field:cve.metrics.cvssMetricV40[type=Primary].cvssData.vectorString || field:cve.metrics.cvssMetricV40[].cvssData.vectorString
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
CVSS vector
cvss_vector
NVDCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
receipt
Source
NVD
Its words
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Read by
field:cve.metrics.cvssMetricV31[type=Primary].cvssData.vectorString || field:cve.metrics.cvssMetricV31[].cvssData.vectorString
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
CWE
cwe
NVDCWE-119, CWE-121, CWE-787
receipt
Source
NVD
Its words
CWE-119, CWE-121, CWE-787
Read by
field:cve.weaknesses[].description[].value
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCCWE-119, CWE-121, CWE-787
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Exploitation
exploitation
NVDpoc
A public proof of concept exists, or exploitation is trivial.
receipt
Source
NVD
Its words
poc
Read by
field:cve.metrics.ssvcV203[].ssvcData.options[].exploitation
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCpoc
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Product
product
NVDRE6500
receipt
Source
NVD
Its words
RE6500
Read by
field:cve.affected[].affectedData[].product
Said since
2026-09-29 17:49 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-09-29 17:49 UTCRE6500
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Severity
severity
NVDHIGH
From 7.0 to 8.9.
receipt
Source
NVD
Its words
HIGH
Read by
field:cve.metrics.cvssMetricV31[type=Primary].cvssData.baseSeverity || field:cve.metrics.cvssMetricV31[].cvssData.baseSeverity
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCHIGH
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
high
Status
status
NVDAnalyzed
receipt
Source
NVD
Its words
Analyzed
Read by
field:cve.vulnStatus
Said since
2026-09-29 09:45 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Technical impact
technical_impact
NVDtotal
The attacker gains full control of the component, or all of its information.
receipt
Source
NVD
Its words
total
Read by
field:cve.metrics.ssvcV203[].ssvcData.options[].technicalImpact
Said since
2026-10-06 11:54 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-10-06 11:54 UTCtotal
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Vendor
vendor
NVDLinksys
receipt
Source
NVD
Its words
Linksys
Read by
field:cve.affected[].affectedData[].vendor
Said since
2026-09-29 17:49 UTC
Last answered
2026-10-06 12:41 UTC
Original
open at the source
2026-09-29 17:49 UTCLinksys
2026-09-29 09:45 UTC—
What the source handed over
{
  "cve": {
    "affected": [
      {
        "affectedData": [
          {
            "product": "RE6500",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6250",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6300",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE6350",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE7000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          },
          {
            "product": "RE9000",
            "vendor": "Linksys",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.013.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.001"
              },
              {
                "status": "affected",
                "version": "1.0.04.002"
              },
              {
                "status": "affected",
                "version": "1.1.05.003"
              },
              {
                "status": "affected",
                "version": "1.2.07.001"
              }
            ]
          }
        ],
        "source": "cna@vuldb.com"
      }
    ],
    "configurations": [
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "92354C9C-D1B2-4143-803D-DE5EF7842184",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "52622B22-2E42-443B-81DA-7C42ECCF0564",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "70728D67-153A-49FA-80E2-0DE9086DA253",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "898FD49F-4225-47FF-822C-9E4FFB5EE192",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "1E3A6A93-D598-4F52-808C-EAA45B468066",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "25647318-6422-418C-99B8-C806FF490028",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*",
                "matchCriteriaId": "0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "4FFD3F65-E520-415D-BAB8-57FACEA5BEC7",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*",
                "matchCriteriaId": "8DC2325A-068F-4B5E-A365-6BF1103E320E",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "D04E83B6-EE99-42EB-AA37-895B1467CEDA",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      },
      {
        "nodes": [
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*",
                "matchCriteriaId": "11F24125-412F-473A-BF34-02284F8DAC2D",
                "vulnerable": true
              }
            ],
            "negate": false,
            "operator": "OR"
          },
          {
            "cpeMatch": [
              {
                "criteria": "cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*",
                "matchCriteriaId": "7424D2C2-BCF4-4B2D-BE59-71B50B13FE77",
                "vulnerable": false
              }
            ],
            "negate": false,
            "operator": "OR"
          }
        ],
        "operator": "AND"
      }
    ],
    "cveTags": [],
    "descriptions": [
      {
        "lang": "en",
        "value": "A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way."
      },
      {
        "lang": "es",
        "value": "Se ha descubierto una falla de seguridad en Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Esta vulnerabilidad afecta a la función RE2000v2Repeater_get_wired_clientlist_setClientsName del archivo mod_form.so. La manipulación del argumento clientsname_0 resulta en desbordamiento de búfer basado en pila. El ataque puede lanzarse remotamente. El exploit ha sido publicado y puede ser explotado. Se contactó al fabricante con antelación sobre esta divulgación, pero no respondió de ninguna manera."
      }
    ],
    "id": "CVE-2025-14136",
    "lastModified": "2026-09-25T23:10:00.463",
    "metrics": {
      "cvssMetricV2": [
        {
          "acInsufInfo": false,
          "baseSeverity": "HIGH",
          "cvssData": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 8.0,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "source": "cna@vuldb.com",
          "type": "Secondary",
          "userInteractionRequired": false
        }
      ],
      "cvssMetricV31": [
        {
          "cvssData": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 2.8,
          "impactScore": 5.9,
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "cvssMetricV40": [
        {
          "cvssData": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "availabilityRequirement": "NOT_DEFINED",
            "baseScore": 7.4,
            "baseSeverity": "HIGH",
            "confidentialityRequirement": "NOT_DEFINED",
            "exploitMaturity": "PROOF_OF_CONCEPT",
            "integrityRequirement": "NOT_DEFINED",
            "modifiedAttackComplexity": "NOT_DEFINED",
            "modifiedAttackRequirements": "NOT_DEFINED",
            "modifiedAttackVector": "NOT_DEFINED",
            "modifiedPrivilegesRequired": "NOT_DEFINED",
            "modifiedSubAvailabilityImpact": "NOT_DEFINED",
            "modifiedSubConfidentialityImpact": "NOT_DEFINED",
            "modifiedSubIntegrityImpact": "NOT_DEFINED",
            "modifiedUserInteraction": "NOT_DEFINED",
            "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
            "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
            "modifiedVulnIntegrityImpact": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "source": "cna@vuldb.com",
          "type": "Secondary"
        }
      ],
      "ssvcV203": [
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "ssvcData": {
            "id": "CVE-2025-14136",
            "options": [
              {
                "exploitation": "poc"
              },
              {
                "automatable": "no"
              },
              {
                "technicalImpact": "total"
              }
            ],
            "role": "CISA Coordinator",
            "timestamp": "2025-12-08T19:43:52.124194Z",
            "version": "2.0.3"
          }
        }
      ]
    },
    "published": "2025-12-06T13:15:59.820",
    "references": [
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Exploit",
          "Third Party Advisory"
        ],
        "url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys2/vuln_65/65.md#poc"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Permissions Required",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?ctiid.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?id.334525"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Third Party Advisory",
          "VDB Entry"
        ],
        "url": "https://vuldb.com/?submit.697983"
      },
      {
        "source": "cna@vuldb.com",
        "tags": [
          "Product"
        ],
        "url": "https://www.linksys.com/"
      }
    ],
    "sourceIdentifier": "cna@vuldb.com",
    "vulnStatus": "Analyzed",
    "weaknesses": [
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-119"
          },
          {
            "lang": "en",
            "value": "CWE-121"
          }
        ],
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "description": [
          {
            "lang": "en",
            "value": "CWE-787"
          }
        ],
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  }
}
—
Every claim, by kind

vulnerability

A security flaw has been discovered in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function RE2000v2Repeater_get_wired_clientlist_setClientsName of the file mod_form.so. The manipulation of the argument clientsname_0 results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
zetlyn/cve-nvd · 2025-12-06
automatable no cvss 8.8 cvss4 7.4 cvss4_vector CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X cvss_vector CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H cwe CWE-119, CWE-121, CWE-787 exploitation poc product RE6500 severity HIGH status Analyzed technical_impact total vendor Linksys source